Characteristics research of water wall temperature and furnace wall thermal load of supercritical W-flame boiler
MA Dafu;ZHOU Wentai;ZHANG Shouyu;HE Xiang;TAO Li;
Abstract:
In view of the cracking phenomenon of front water wall of a 600 MW supercritical W-flame boiler,the thermocouples on the fireside and backfiring surface of the water wall were installed. The influence of different location of the temperature and thermal load of water wall characteristics under the influence of the typical operating conditions,the oxygen concentration,the pulverized coal fineness and Fdampers opening under the process of boiler start-up and 600 MW load conditions was investigated. The test results show that due to the existence of the the angle of flame break,the flue gas flow is close to the front wall,the thermal load on the front wall is higher than that on the back wall under high load,and the thermal load on the front wall is the highest at 36.8 m,and the furnace width is up to 32 meters,which increases the possibility of water wall tearing. The F damper scale of rear wall pressing front wall can reduce the thermal load of front wall water wall as well as the possibility of water wall tearing. The thermal load decreases rapidly along with the furnace height. For the former wall,the average dimensionless thermal load at 36.8,44.0 and 48.5 m elevation of the former wall is 0.75,0.50 and 0.19 respectively.In the process of boiler start-up,the temperature difference between the the fireside and backfiring surface gradually increases,and the thermal load on the wall gradually increases after the pulverized coal is put into operation. Although the wall temperature of backfired surface has transient overtemperature when startingmill,the overall thermal load is low and the water wall is relatively safe. Oxygen concentration has little effect on the overall thermal load in the furnace. Under the condition of full load,the oxygen content is recommended to maintain at 2% under the premise of low CO concentration in the rear region. The thermal load decreases slightly after the pulverized coal become smaller. It is suggested that the scale of the folding dampers in condition 8 should be adopted without considering the coal mill output.
Key Words: supercriticality;W-flame boiler;water wall;thermal load
Foundation: 国家电力投资集团课题资助项目(201805559)
Authors: MA Dafu;ZHOU Wentai;ZHANG Shouyu;HE Xiang;TAO Li;
DOI: 10.13226/j.issn.1006-6772.CFB20032701
References:
- [1]袁颖,相大光.我国W火焰双拱锅炉燃烧性能调查研究[J].中国电力,1999(11):1-6.YUAN Ying,XIANG Daguang. Survey and study on combustion performance of W-flame double arch boiler[J]. China Power,1999(11):1-6.
- [2]阎维平,高正阳,姜平.300 MW机组W型火焰锅炉燃烧调整试验研究[J].动力工程学报,1999,19(1):23-26.YAN Weiping,GAO Zhengyang,JIANG Ping. Combustion experiments of the 300 MW"W"type flame boiler[J].Power Engineering.1999,19(1):23-26.
- [3]张海,吕俊复,徐秀清,等.W型火焰锅炉燃烧问题的分析和解决方法[J].动力工程学报,2005,25(5):628-632.ZHANG Hai,LYU Junfu,XU Xiuqing,et al. Analysis and possible solutions for the combustion problems of boilers with arc-firing[J]. Power Engineering,2005,25(5):628-632.
- [4]车刚,郝卫东,郭玉泉.W型火焰锅炉及其应用现状[J].电站系统工程,2004,20(1):38-40.CHE Gang,HAO Weidong,GUO Yuquan. W-shape flame boiler and its application[J]. Power Systems Engineering,2004,20(1):38-40.
- [5]程智海,金鑫,张富祥,等.W火焰锅炉的燃烧调整[J].动力工程学报,2009,29(2):129-133.CHENG Zhihai,JIN Xin,ZHANG Fuxiang,et al. Combustion adjusting of W flame boilers[J]. Power Engineering,2009,29(2):129-133.
- [6]杨勇.1 000 MW超超临界压力直流锅炉螺旋管圈水冷壁的水动力及传热特性试验研究[D].上海:上海发电设备成套设计研究院,2010YANG Yong. Experimental research on the dynamic and heat transfer characteristics of 1 000 MW USC pressure once-through boiler spiral water-wall[D]. Shanghai:Shanghai Power Equipment and Research Institute,2010.
- [7]徐金苗,李伟科,吴阿峰,等.600 MW超临界W火焰锅炉水冷壁拉裂研究[J].南方能源建设,2017,4(1):49-52.XU Jinmiao,LI Weike,WU Afeng,et al. Research on 600 MW supercritical W-flame water wall cracking[J]. Southern Energy Construction,2017,4(1):49-52.
- [8]伍天海,鄢晓忠,符慧林,等.600 MW超临界W型火焰锅炉水冷壁爆管原因分析[J].长沙理工大学学报(自然科学版),2013,10(4):86-92.WU Tianhai,YAN Xiaozhong,FU huilin,et al. Analysis of water wall's tube explosion in 600 MW W-flame supercritical boiler[J].Journal of Changsha University of Science and Technology(Natural science),2013,10(4):86-92.
- [9]杨勇,俞谷颖,陈端雨,等.超临界压力W火焰锅炉炉膛水冷壁热负荷分布的试验研究[J].动力工程学报,2015,35(6):429-436.YANG Yong,YU Guyin,CHEN Duanyu,et al. Experimental study on heat load distribution of water wall in furnace of supercritical pressure W flame boiler[J]. Power Engineering,2015,35(6):429-436.
- [10]王为术,朱晓静,毕勤成,等.超临界W型火焰锅炉垂直水冷壁低质量流速条件下热敏感性研究[J].中国电机工程学报,2010,31(20):15-21.WANG Weishu,ZHU Xiaojing,BI Qincheng,et al. Study on thermal sensitivity characteristics of vertical membrane water wall in supercritical pressure W shaped flame boiler[J]. Proceedings of the CSEE,2010,31(20):15-21.
- [11]吴燕华,杨冬,陈功名,等.首台600 MW超临界W火焰锅炉水动力特性计算及分析[J].中国电力,2013,46(2):24-30.WU Yanhua,,YANG Dong,CHEN Gongming,et al. Calculation and analysis of hydrodynamic characteristics for first 600-MW supercritical down-fired boiler[J]. China Power,2013,46(2):24-30.
- [12]沈艳荣,杨冬,王龙,等.600 MW超临界W火焰锅炉流动不稳定性数值分析[J].西安交通大学学报,2015,49(5):68-72.SHEN Yangrong,YANG Dong,WANG Long,et al. Numercial analysis on the flow instability of a 600 MW supercritical W flame boiler[J]. Journal of Xi'an Jiaotong University,2015,49(5):68-72.
- [13] SHEN Y,YANG D,SHEN Z,et al. Modeling and analysis of flow instability of the water wall in a 600 MW supercritical W-shaped boiler[J]. Applied Thermal Engineering,2016,99:325-333.
- [14]杨晨,赵丽,何航行.600 MW超临界W火焰锅炉燃烧特性及水冷壁分布参数混合模拟[J].热科学与技术,2014,13(2):157-164.YANG Chen,ZHAO Li,HE Hangxing. Hybird simulation for combustion characteristics of 600 MW supercritical unit with W-flame furnace and distributed parameters of waterwall[J].Journal of Thermal Science and Technology,2014,13(2):157-164.
- [15]高正阳,崔伟春,杨毅栎,等.火焰中心高度对W型火焰锅炉燃烧影响的数值模拟研究[J].热力发电,2009,38(11):23-27.GAO Zhengyang,CUI Weichun,YANG Yili,et al. Study on numerical simulation concerning of flame center height upon combustion in W-shaped flame boiler[J]. Thermal Power,2009,38(11):23-27.
- [16]梁晓宏,樊建人,岑可法.W型火焰煤粉锅炉炉内三维流动和燃烧过程的数值模拟[J].中国电机工程学报,2009,38(11):23-27.LIANG Xiaohong,FAN Jianren,CEN Kefa. Numerical simulation of the flow and vombustion processes in three-dimensional,Wshaped boiler furnace[J]. Proceedings of the CSEE,2009,38(11):23-27.
- [17]周武,陈建梅,陈灿,等.超临界W形火焰锅炉炉内过程数值模拟[J].动力工程学报,2011,31(1):7-11.ZHOU Wu,CHEN Jianmei,CHEN Can,et al. Numerical simulation of process in the furnace of a supercritical W-flame boiler[J]. Power Engineering,2011,31(1):7-11.
- [18]徐仁德,张今朝.由实测管壁温度确定炉膛壁面热负荷的方法[J].动力工程学报,1986,6(3):48-53,84.XU Rende,ZHANG Jinzhao. Method for determining the heat load of furnace wall surface by the measured pipe wall temperature[J]. Power Engineering,1986,6(3):48-53,84.
- MA Dafu
- ZHOU Wentai
- ZHANG Shouyu
- HE Xiang
- TAO Li
- Shanghai Power Equipment Research Institute Co.
- Ltd.
- School of Energy and Power Engineering
- Shanghai University of Science and Technology
- MA Dafu
- ZHOU Wentai
- ZHANG Shouyu
- HE Xiang
- TAO Li
- Shanghai Power Equipment Research Institute Co.
- Ltd.
- School of Energy and Power Engineering
- Shanghai University of Science and Technology